My car ac a year ago stopped working on settings 123 only works on 4 I did the research so I do know it is the blower motor an ha

Car ac blower motor stopped working on settings 123 a year ago, only works on setting 4 all of a sudden is only blowing cold now for 5 maybe 10 mins , I knew eventual I would have to replace motor but sometimes bigger issues come first as we all know, I've done my research although I'm no mechanic so no leaks no foul smells no debree an freon is full also I just replaced ac belt , the blower is the only thing in my research that resembles what is happening, obviously do not have funds to get checked professional , of course I know blower has to be replaced anyway just would like secon
Experienced mechanics share their insights in answering this question :
In your application, there is a replaceable blower motor resistor block. The resistor block permits multi-speed operation of the fan. If some fan speed settings work, but not others, the first thing to do is test the resistor block with a volt ohmmeter. If you desire testing, and replacement, as needed, please request a blower motor/resistor block diagnostic and the responding certified mechanic will get this taken care of for you.

With regard to the A/C system, if gauge pressures (high and low) are normal when the system does operate, there are really only two principle possibilities for intermittent operation. One is circulating moisture in the system (due to a saturated dryer) which periodically freezes (and thaws) at the expansion valve and the other is a failure in the A/C control system, that is the clutch, sensors, and other electronics that control the compressor cycling. The cause of the problem can be readily found if you request an A/C system diagnostic. If you have further questions or concerns, do not hesitate to re-contact YourMechanic as we are always here to help you.

How to Identify and Fix Common car Problems ?

Our sources include academic articles, blog posts, and personal essays from experienced mechanics :

Cooling fans can stop working properly for a number of different reasons; they might have blown fuses, an electrical short, or could have been cracked by debris from the road. Fortunately, this is fairly simple to fix; your mechanic should be able to replace it quickly and get you back on the road.
Your car`s air-conditioning stopped working most likely because of a freon leak or a bad compressor. While these causes may be the simple to spot reasons that your air-conditioning isn`t cooling in your vehicle, a dirty cabin filter or a bad belt could also be the problem.
Problems include dirty filters, broken wires, poor voltage supply and faulty limit switch or capacitor. You can test your limit switch with a multimeter, and clean the blower motor`s wire coils. If this doesn`t work, you may need to replace your furnace blower motor.
A fuse is often located on the resistor board. The fuse only protects the low and medium blower speeds. High speed will still work if the resistor fuse is blown.
Blocked or Broken Condenser

It works to turn the freon gases back into liquid form. If the condenser has gone bad, it will not be able to process the freon and produce cool air. A broken condenser might malfunction when there is a cut back in power as when the car is idling or running the AC purely on the battery.

Why Is My AC Fan Not Spinning? In short, common issues that can cause an air conditioning unit fan to stop spinning are electrical issues, problems with the capacitor, contactor issues, a burnt out air conditioner motor, a broken fan belt, or clogged air filter.
If the resistor shorts or fails, it may cause the blower motor to remain stuck on one fan speed. The heating and air conditioning systems may still function at one speed, however the resistor will have to be replaced in order for full functionality to be restored.
One of the first symptoms of a problem with the blower motor relay is a blower motor that does not function. As the relay is the switch that supplies current to the blower motor, if it fails internally, then power may be cut off from the blower motor circuit causing the motor to no longer function.
Many vehicles have two fuses for the blower motor, one in the interior fuse block and the other under the hood. The blower motor is usually under the dashboard on the passenger side.
Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.
Look for it first around on the exterior of your machine, especially along the bottom edge near the ground. An AC`s reset button is typically red and visible, so it should be easy to spot. If you don`t see a reset button on the outside, it could be located inside the unit behind the service panel.
To test a blower motor with a multimeter, first set the multimeter to the “resistance” or “ohms” setting. Then, touch the probes of the multimeter to the terminals on the blower motor. If the resistance reading is infinite, that means there is an open circuit and the blower motor is defective.
Clogged air filters are one of the most common reasons a thermostat clicks but AC does not turn on. A filter cleans the air before it circulates throughout your home, trapping dirt particles, dust, and pollen. Over time, these contaminants will clog the filter, limiting airflow to the HVAC system or furnace.
If your central AC is not blowing cold air, the refrigerant may be the problem. The unit could be running low and need additional refrigerant added. The most likely cause of this is a leak. A leak not only keeps the AC unit from cooling properly, but also it can cause other issues within the home.
The blower motor resistor in your car is the part that is responsible for pushing air through the vents when using the air conditioner or heater.
The blower motor resistor is designed to last for the car`s lifespan. In most cases, these resistors will wear out long before the car does. Usually, the wear that the blower motor resistor has is due to the constant use that it gets and the heat that it is exposed on a regular basis.
The blower resistor is connected in series with the blower fan. This means that the current running through the blower motor, and thus its speed, is controlled by the resistor value.
These are different components. The blower motor high relay will affect high speed blower operation. The blower motor resistor will vary the lower speeds.
A fixed composition resistor normally fails in an open configuration when overheated or overly stressed due to shock or vibration. Excessive humidity may cause an increase in resistance. A variable composition resistor may wear after extensive use, and worn away particles may cause high resistance short circuits.
However, they must pass a solderability test if they are older than 2 years and less than 5 years old. Passive components like capacitors and resistors have a shelf life of about 5 years if there is no proof of corrosion.
A majority of cars use one blower for the HVAC system. Some large vehicles such as vans and SUVs have two; one in the front and another in the rear. Blower motor features and configurations vary slightly.
How much does a blower motor resistor cost? To replace the blower motor resistor, it would cost you anywhere between $50 to$150 – this includes the cost of equipment and labor. However, by doing it yourself at home, you can save up to $70.
The heating and air-conditioning system uses several resistors to supply the desired airflow by sending power to the blower motor.

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

My car ac a year ago stopped working on settings 123 only works on 4 I did the research so I do know it is the blower motor an ha
ANSWER : In your application, there is a replaceable blower motor resistor block. The resistor block permits multi-speed operation of the fan. If some fan speed settings work, but not others, the first thing to do is test the resistor block with a volt ohmmeter. If you desire testing, and replacement, as needed, please request a blower motor/resistor block diagnostic and the responding certified mechanic will get this taken care of for you.

With regard to the A/C system, if gauge pressures (high and low) are normal when the system does operate, there are really only two principle possibilities for intermittent operation. One is circulating moisture in the system (due to a saturated dryer) which periodically freezes (and thaws) at the expansion valve and the other is a failure in the A/C control system, that is the clutch, sensors, and other electronics that control the compressor cycling. The cause of the problem can be readily found if you request an A/C system diagnostic. If you have further questions or concerns, do not hesitate to re-contact YourMechanic as we are always here to help you.

My AC does not always work. If I fiddle with the blower knob I can ususally get it to work on the lowest setting.
ANSWER : Hi There,
It sounds like you may have a faulty blower motor resistor. The highest speed setting may still work because in most cars in the highest fan speed settings the current bypasses the blower motor resistor. In some cars, if the resistor is failed, the fan may stop working completely. Another reason a blower motor resistor may fail is when the blower motor has a mechanical problem or when a foreign object jams the blower motor fan blade and prevents it from spinning freely. This leads to increased current through the resistor and causes it to overheat and fail. I would suggest having an expert from YourMechanic come to your location to diagnose your system to determine what may be causing the fan not to work properly.

When I turn on my AC the radiator fans do not turn on. The fans do come on when the car warms up so I know they are working and the fuses are good. The AC compressor does come on and the air blows ice cold when the car is moving. Car is a 2006 Chrysler Sebring Sedan 2.7l v6.
ANSWER : The control circuit for the fans needs to be checked. For example, there is usually a condenser fan relay in the A/C electrical controls. There could be a fault with that relay and/or wiring problems, perhaps even just a loose connection, blown or loose fuse, and so forth. To resolve something like this, the recommended service is an electrical component diagnostic. If you request that diagnostic service, the responding certified mechanic will get the problem pinpointed and resolved. If you have further questions or concerns, do not hesitate to re-contact YourMechanic as we are always here to help you.

Honda Civic 2008. AC stopped working suddenly and engine check light came ON for a day.Next day AC worked and no engine light.
ANSWER : Hi there. In both cases, when an AC system is not working and a warning light is coming on the dashboard, typically a professional mechanic will complete the same initial inspection, which is to download the stored error codes that triggered the warning light initially. This tends to give them an idea as to what is causing the problems. This could be something as simple as an electrical relay that is faulty or loose or an indication of a computer related "glitch". Either way, the best way to move forward is to have a professional mobile mechanic complete a check engine light inspection.

If I get my blower motor replaced, do I also have to have my Ac recharged after replacing blower motor?
ANSWER : The blower motor on this vehicle is a simple removal and installation and does not require anything to be touched on the A/C. The refrigerant does not have to be removed. The only component that has to be removed is the glove box under cover to get to the blower motor.

My front heat is not working but rear heat blowing. Had blower motor replaced 4 years ago… do u think it couldBe that again
ANSWER : It is entirely possible that the blower motor has failed. When the blower motor was last replaced, was the blower motor resistor replaced as well ? The resistor is also a big possibility. The blower motor resistor is used to change the voltage to the blower motor to vary the fan speed. If it was not in place to reduce or increase voltage, the fan would run at one speed only – high. The resistor can show signs of failure in a number of ways. It can fail all together so the fan will not work at all. It can also fail on certain speeds. For example, if your blower speed switch has 4 positions, it may work on 1 and 4, and not work on speeds 2 and 3. Other possible faults can be the relay for the front blower as well as the blower switch in the climate controls. A certified technician can look into why the front blower motor is not working and find the exact cause for you.

Blower Motor only working on highest speed.
ANSWER : You mentioned that you started to smell something. This may be a sign that the blower controller or the resistor was burnt out when it was hooked up wrong. You should try replacing the blower controlling resistor that you hooked up wrong. But like you mentioned, it could also be a fuse problem that has shorted. If you would like to have this looked at, have a certified technician, like one from YourMechanic inspect the wiring and determine what should be done.

My heat in my car stopped working two days ago and now my car is overheating. I put antifreeze in my car and it’s still overheating 2006 Pontiac Grand Prix
ANSWER : Hi there – you may have 2 related events here, a coolant leak, and a problem with the heater system. The current issue may be air inside the cooling system, which can cause overheating, and a lack of heater function. The lack of heater function could have 5 causes: the engine is not getting up to correct temperature (center of the gauge) due to a malfunctioning thermostat, the heater control valve is not letting hot coolant into the heater core, there is a restriction in the heater system that is preventing adequate hot coolant flow through the heater core, the heater fan is not working to transfer heat from the heater core to warm air for the passenger compartment, or the air blend doors inside the heater are not working properly to route warm air to the desired vents. I would recommend a heater system inspection](https://www.yourmechanic.com/services/heater-is-not-working-inspection) by a mobile, professional mechanic, such as one from YourMechanic, who will come to your location, diagnose this problem, give you an accurate assessment of damage and cost estimate for repairs.